Double Beam UV VIS Spectrophotometer TRDUV-601

Double Beam UV VIS Spectrophotometer TRDUV-601

  • Spectrum Bandwidth : 2 nm
  • Wavelength Range : 190 to 1100 nm
  • Monochromatic Type : Czerny-Turner
  • Grating : 1600 lines/mm
  • Detector : Silicon Photocell
  • Wavelength Accuracy : ± 0.3 nm
  • Wavelength Repeatability : ≤ 0.1 nm
  • Wavelength Scanning Speed : Fast, medium, and slow
  • Light Source Switching Wavelength : 340 nm
  • Stray Light : ≤ 0.02% (measured by NaI at 220 nm) (measured at NaNO2 at 360 nm)
  • Photometric Range : 0.0 to 200.0% T -0.301 to 4.000 A 0.000 to 9999 C
  • Photometric Accuracy : ± 0.3% T ± 0.002Abs (0 to 0.5A) ± 0.004Abs (0.5 to 1A)
  • Photometric Repeatability : ≤ 0.15% T 0.001Abs (0 to 0.5A) 0.002Abs (0.5 to 1A)
  • Baseline Flatness : ≤ ± 0.0008A(200 to 1090 nm)
  • Noise : 100%(T) noise ≤ 0.1% (T), 0% (T) noise  ≤ 0.02% (T)
  • Baseline Drift : ± 0.0004 Abs / h
  • Power : AC220v± 22v, 50Hz± 1Hz, 200W
  • Light Source : Hamamatsu D2 lamp, Osram halogen tungsten lamp.
  • Com Port : USB
  • Packing Size : 740 mm×630 mm×450 mm
  • Weight : 35 Kg, 0.21 m³

$23.34

Double Beam UV VIS Spectrophotometer TRDUV-602

Double Beam UV VIS Spectrophotometer TRDUV-602

  • Spectrum Bandwidth : 0.5 nm, 1nm, 2 nm, 4 nm, 5 nm
  • Wavelength Range : 190 to 1100 nm
  • Monochromatic Type : Czerny-Turner
  • Grating : 1600 lines/mm
  • Detector : Silicon Photocell
  • Wavelength Accuracy : ± 0.3 nm
  • Wavelength Repeatability : ≤ 0.1 nm
  • Wavelength Scanning Speed : Fast, medium, and slow
  • Light Source Switching Wavelength : 340 nm
  • Stray Light : ≤ 0.02% (measured by NaI at 220 nm) (measured at NaNO2 at 360 nm)
  • Photometric Range : 0.0 to 200.0% T -0.301 to 4.000 A 0.000 to 9999 C
  • Photometric Accuracy : ± 0.3% T ± 0.002Abs (0 to 0.5A) ± 0.004Abs (0.5 to 1A)
  • Photometric Repeatability : ≤ 0.15% T 0.001Abs (0 to 0.5A) 0.002Abs (0.5 to 1A)
  • Baseline Flatness : ≤ ± 0.0008A(200 to 1090 nm)
  • Noise : 100%(T) noise ≤ 0.1% (T), 0% (T) noise  ≤ 0.02% (T)
  • Baseline Drift : ± 0.0004 Abs / h
  • Power : AC220v± 22v, 50Hz± 1Hz, 200W
  • Light Source : Hamamatsu D2 lamp, Osram halogen tungsten lamp.
  • Com Port : USB
  • Packing Size : 740 mm×630 mm×450 mm
  • Weight : 35 Kg, 0.21 m³

$23.34

Double Beam UV VIS Spectrophotometer TRDUV-603

Double Beam UV VIS Spectrophotometer TRDUV-603

  • Monochromatic type : Czerny turner
  • Focal length : 160 mm
  • Wavelength Range : 190 to 1100 nm
  • Band Width : 1.8 nm
  • Wavelength Accuracy : ±0.3 nm
  • Wavelength Repeatability : ≤0.01 nm
  • Photometric Display Range : 0.0 to 200 .0% T , -0.301 to 4.000 A , 0.000 to 9999 C
  • Photometric Accuracy : ±0.3% T(0 to 100%T) / ±0.002A(0 to 0.5A) / ±0.004A(0.5A to1A)
  • Photometric Repeatability : 0.15% T(0 to 100%T) / ±0.001A(0 to 0.5A) / ±0.002A(0.5A to 1A)
  • Photometric Mode : T,A,C,E
  • Stray Light : ≤0.03% τ (220nm NaI, 360 nm NaNO2)
  • Stability : 0.0005A/h500 nm
  • Detector : Import Silicon Photodiode
  • Scanning speed : Fast-medium-slow
  • Power Requirement : AC 220 V±22 50 Hz±1 Hz,200 W
  • Baseline Flatness : ≤0.002A(200 to1090 nm)
  • Grating : 1200 lines/mm
  • Drifting : ≤0.0009 Abs/30 min
  • Noise : 100 % (T)≤0.15 % (T);  0 % (T)≤0.1 % (T)
  • Dimensions(W×D×H) : 74×63×45 Cm
  • Weight : 35 Kg

$23.34

Double Beam UV VIS Spectrophotometer TRDUV-604
Double Beam UV VIS Spectrophotometer TRDUV-604
  • Monochromatic type : Czerny turner
  • Focal length : 160 mm
  • Wavelength Range : 190 to 1100nm
  • Band Width : 2 nm
  • Wavelength Accuracy : ±0.3 nm
  • Wavelength Repeatability : ≤0.01 nm
  • Photometric Display Range : 0.0 to 200 .0% T, -0.301 to 4.000 A, 0.000 to 9999 C
  • Photometric Accuracy : ±0.3% T(0 to 100%T), ±0.002A(0 to 0.5A), ±0.004A(0.5A to 1A)
  • Photometric Repeatability : 0.15% T(0 to 100%T), ±0.001A(0 to 0.5A) / ±0.002A(0.5A to 1A)
  • Photometric Mode : T,A,C,E
  • Stray Light : ≤0.03% τ (220nm NaI, 360nm NaNO2)
  • Stability : 0.0005A/h@500 nm
  • Detector : Import Silicon Photodiode
  • Scanning speed : Fast-medium-slow
  • Power Requirement : AC220V±22 50Hz±1Hz,200W
  • Baseline Flatness : ≤0.002A(200 to 1090 nm)
  • Grating : 1200 lines/mm
  • Drifting : ≤0.0009 Abs/30 min (250 nm and 500 nm after 2h warm-up)
  • Dimensions(W×D×H) : 74×63×45 Cm
  • Weight : 35    Kg

$23.34