Quote Form

Please fill out the form below and we will get back to you as soon as possible.


Atomic Absorption Spectrophotometer TRAS-601

Atomic Absorption Spectrophotometer TRAS-601

  • Wavelength Range : 190 to 900 nm
  • Wavelength Accuracy : £ ±0.5 nm
  • Wavelength Repeatability : £ 0.3 nm (single direction)
  • Spectrum Bandwidth : 0.2 nm, 0.4 nm, 0.7nm, 1.4 nm, 2.4 nm, 5.0 nm
  • Resolution : <40%
  • Baseline stability : ±0.004 Abs/30 min
  • Characteristic concentration of copper : £ 0.04 mg/ml/1%
  • Detection limit of copper : £0.008 mg/ml
  • Background calibration ability : Greater than 30 times
  • RS232 : including
  • Printer : optional
  • Power supply : 220V 3A, 50 Hz
  • Package Dimensions : 1220×770×730 mm (Main instrument) 800×400×900 mm ( Accessories )
  • Weight : 160 Kg

$23.34

Atomic Absorption Spectrophotometer TRAS-701

Atomic Absorption Spectrophotometer TRAS-701

  • Wavelength range  : 190 to 900 nm
  • Spectral bandwidth : 0.1, 0.2, 0.4, 1.0 and 2.0 nm
  • Accuracy of the wavelength : ±0.15 nm
  • Receptivity of the wavelength  : ≤0.04 nm
  • Baseline stability : ≤0.002A/30 min (Cu)
  • Characteristic viscosity : 0.02 μg/ml/1% (Cu)
  • Checking limit : 0.004 μg/ml (Cu)
  • Preciseness : 0.005
  • Grating : 1800 lines/ mm
  • Inflamer : All-metal titanium burner
  • Atomizer  : Effective glass atomizer
  • Lamp stand : 8
  • D2 background correction ability : When the background is 1 A, the background ability should be deducted not less than 50 times, self-absorption background deduction method
  • Size  : 700 mm×550 mm×450 mm  
  • weight : 75 Kg
  • Power source : 220V±22V AC
  • Flame System : 100 mm, ≤0.006 A/30 min, ≤0.025 μg/ml/1%, ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008 μg/ml), Can Automatically cut off the gas when The pressure is not enough, The power is off, flameout and unconformity of the burner.
  • Graphite furnace : 3000 ℃, ≥2000 ℃/S, Cd≤0.5×10 to12 g
     Cu≤0.5×10 to 11 g, Cu≤3% Cd≤3 %, 550 mm×450 mm×300 mm  65 Kg
  • Power source and power : 220 V±22 V  AC  7000 W

$23.34

Double Beam UV VIS Spectrophotometer TRDUV-601
Double Beam UV VIS Spectrophotometer TRDUV-601
  • Spectrum Bandwidth : 2 nm
  • Wavelength Range : 190 to 1100 nm
  • Monochromatic Type : Czerny-Turner
  • Grating : 1600 lines/mm
  • Detector : Silicon Photocell
  • Wavelength Accuracy : ± 0.3 nm
  • Wavelength Repeatability : ≤ 0.1 nm
  • Wavelength Scanning Speed : Fast, medium, and slow
  • Light Source Switching Wavelength : 340 nm
  • Stray Light : ≤ 0.02% (measured by NaI at 220 nm) (measured at NaNO2 at 360 nm)
  • Photometric Range : 0.0 to 200.0% T -0.301 to 4.000 A 0.000 to 9999 C
  • Photometric Accuracy : ± 0.3% T ± 0.002Abs (0 to 0.5A) ± 0.004Abs (0.5 to 1A)
  • Photometric Repeatability : ≤ 0.15% T 0.001Abs (0 to 0.5A) 0.002Abs (0.5 to 1A)
  • Baseline Flatness : ≤ ± 0.0008A(200 to 1090 nm)
  • Noise : 100%(T) noise ≤ 0.1% (T), 0% (T) noise  ≤ 0.02% (T)
  • Baseline Drift : ± 0.0004 Abs / h
  • Power : AC220v± 22v, 50Hz± 1Hz, 200W
  • Light Source : Hamamatsu D2 lamp, Osram halogen tungsten lamp.
  • Com Port : USB
  • Packing Size : 740 mm×630 mm×450 mm
  • Weight : 35 Kg, 0.21 m³

$23.34

Double Beam UV VIS Spectrophotometer TRDUV-602
Double Beam UV VIS Spectrophotometer TRDUV-602
  • Spectrum Bandwidth : 0.5 nm, 1nm, 2 nm, 4 nm, 5 nm
  • Wavelength Range : 190 to 1100 nm
  • Monochromatic Type : Czerny-Turner
  • Grating : 1600 lines/mm
  • Detector : Silicon Photocell
  • Wavelength Accuracy : ± 0.3 nm
  • Wavelength Repeatability : ≤ 0.1 nm
  • Wavelength Scanning Speed : Fast, medium, and slow
  • Light Source Switching Wavelength : 340 nm
  • Stray Light : ≤ 0.02% (measured by NaI at 220 nm) (measured at NaNO2 at 360 nm)
  • Photometric Range : 0.0 to 200.0% T -0.301 to 4.000 A 0.000 to 9999 C
  • Photometric Accuracy : ± 0.3% T ± 0.002Abs (0 to 0.5A) ± 0.004Abs (0.5 to 1A)
  • Photometric Repeatability : ≤ 0.15% T 0.001Abs (0 to 0.5A) 0.002Abs (0.5 to 1A)
  • Baseline Flatness : ≤ ± 0.0008A(200 to 1090 nm)
  • Noise : 100%(T) noise ≤ 0.1% (T), 0% (T) noise  ≤ 0.02% (T)
  • Baseline Drift : ± 0.0004 Abs / h
  • Power : AC220v± 22v, 50Hz± 1Hz, 200W
  • Light Source : Hamamatsu D2 lamp, Osram halogen tungsten lamp.
  • Com Port : USB
  • Packing Size : 740 mm×630 mm×450 mm
  • Weight : 35 Kg, 0.21 m³

$23.34

Double Beam UV VIS Spectrophotometer TRDUV-603

Double Beam UV VIS Spectrophotometer TRDUV-603

  • Monochromatic type : Czerny turner
  • Focal length : 160 mm
  • Wavelength Range : 190 to 1100 nm
  • Band Width : 1.8 nm
  • Wavelength Accuracy : ±0.3 nm
  • Wavelength Repeatability : ≤0.01 nm
  • Photometric Display Range : 0.0 to 200 .0% T , -0.301 to 4.000 A , 0.000 to 9999 C
  • Photometric Accuracy : ±0.3% T(0 to 100%T) / ±0.002A(0 to 0.5A) / ±0.004A(0.5A to1A)
  • Photometric Repeatability : 0.15% T(0 to 100%T) / ±0.001A(0 to 0.5A) / ±0.002A(0.5A to 1A)
  • Photometric Mode : T,A,C,E
  • Stray Light : ≤0.03% τ (220nm NaI, 360 nm NaNO2)
  • Stability : 0.0005A/h500 nm
  • Detector : Import Silicon Photodiode
  • Scanning speed : Fast-medium-slow
  • Power Requirement : AC 220 V±22 50 Hz±1 Hz,200 W
  • Baseline Flatness : ≤0.002A(200 to1090 nm)
  • Grating : 1200 lines/mm
  • Drifting : ≤0.0009 Abs/30 min
  • Noise : 100 % (T)≤0.15 % (T);  0 % (T)≤0.1 % (T)
  • Dimensions(W×D×H) : 74×63×45 Cm
  • Weight : 35 Kg

$23.34

Double Beam UV VIS Spectrophotometer TRDUV-604

Double Beam UV VIS Spectrophotometer TRDUV-604

  • Monochromatic type : Czerny turner
  • Focal length : 160 mm
  • Wavelength Range : 190 to 1100nm
  • Band Width : 2 nm
  • Wavelength Accuracy : ±0.3 nm
  • Wavelength Repeatability : ≤0.01 nm
  • Photometric Display Range : 0.0 to 200 .0% T, -0.301 to 4.000 A, 0.000 to 9999 C
  • Photometric Accuracy : ±0.3% T(0 to 100%T), ±0.002A(0 to 0.5A), ±0.004A(0.5A to 1A)
  • Photometric Repeatability : 0.15% T(0 to 100%T), ±0.001A(0 to 0.5A) / ±0.002A(0.5A to 1A)
  • Photometric Mode : T,A,C,E
  • Stray Light : ≤0.03% τ (220nm NaI, 360nm NaNO2)
  • Stability : 0.0005A/h@500 nm
  • Detector : Import Silicon Photodiode
  • Scanning speed : Fast-medium-slow
  • Power Requirement : AC220V±22 50Hz±1Hz,200W
  • Baseline Flatness : ≤0.002A(200 to 1090 nm)
  • Grating : 1200 lines/mm
  • Drifting : ≤0.0009 Abs/30 min (250 nm and 500 nm after 2h warm-up)
  • Dimensions(W×D×H) : 74×63×45 Cm
  • Weight : 35    Kg

$23.34

Fluorescence Spectrophotometer TRFS-601
Fluorescence Spectrophotometer TRFS-601
  • Exciting Optical Filters : Interface optical filter (10 nm bandwidth)
  • Wavelength : 365 nm
  • Emission Monochromatic : C-T diffraction grating (EM 200 to 900 nm )
  • Wavelength Accuracy : ±1 nm
  • Wavelength Repeatability : ≤0.5 nm
  • Sensitivity : S/N≥150
  • Linearity Deviation : ≥0.995
  • Stability : Better than 1.5 %/10min
  • Power : 220V±22v 50HZ±1HZ
  • Display Value : 0.00 to 600.0
  • Interface : USB2.0
  • Size : 550×510×365 mm
  • Weight : 13 kg

$23.34

Micro-Spectrophotometer TRMS-601
Micro-Spectrophotometer TRMS-601
  • Light Path : 1mm
  • sample Volume : 1 to 2μL
  • Detection Range : 190 to 850 nm
  • Wavelength Range : 190 to 1100 nm
  • Wavelength Accuracy : ± 1nm
  • Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
  • Accuracy of absorbance : 0.002 Abs
  • Absorbance Accuracy : 1% (0.76 absorbance at 350nm)
  • Absorbance Range : 0.02 to 15Abs, equivalent to 10mm
  • Detection Time : less than 3 s
  • Nucleic acid range : 1 to 750 mg/μl, dsDNA
  • Protein measurement range : 0.1 to 40 mg/ml, BSA
  • Sample measurement time : less than 5 seconds
  • Built-in Method : Nucleic Acid, Protein, Full Wavelength Scan
  • Machine Size : 20×30×20 cm
  • Machine Weight : 2.8 kg
  • Light Source : Xenon lamp
  • Detector : The 3684-element linear silicide CCD array

$23.34

Micro-spectrophotometer TRMS-602

Micro-spectrophotometer TRMS-602

  • Optical Path : 1/0.5/0.05 mm automatic conversion
  • Optical Range : 190 to 1100 nm
  • Sample Volume : 0.3 to 2.0 μl
  • Light Source : Long-life Xenon lamp
  • Detector : 3864 linear CCD array
  • Wavelength scanning Range : 190 to 850 nm
  • Wavelength Accuracy : ±1 nm
  • Wavelength Resolution : 2 nm (FWHM Hg 546 nm)
  • Absorbance Accuracy : 0.002 Abs
  • Absorbance Range : 1% (0.76 absorbances at 350 nm)
  • Nucleic acid Range : 0.002 to 300 Abs (equivalent to 10mm optical path)
  • Protein Range : 0.4 to 15000 ng/μl (ds-DNA)
  • Detection Time : 0.01 to 400 mg/ml (BSA)
  • Machine Size : less than 3s
  • Weight : 20×30×20 cm

$23.34

Micro-spectrophotometer TRMS-603

Micro-spectrophotometer TRMS-603

  • Wavelength scanning Range : 190 to 850 nm
  • Wavelength Accuracy : ±1 nm
  • Optical Path : 1/0.5/0.05 mm automatic conversion
  • Optical Range : 190 to 1100 nm
  • Sample Volume : 0.3 to 2.0 μl
  • Wavelength Resolution : 2 nm (FWHM Hg 546n m)
  • Cuvette wavelength Range : 200 nm to 850 nm
  • Trial cuvette Specifications (light path) : 1/2/5/10 mm
  • Cuvette minimum Volume : 50 μl
  • Sample level Height : 5 mm
  • Type : Recyclable micro cuvette
  • Cuvette darkroom : standard cuvette darkroom
  • Absorbance Accuracy : 2 nm (FWHM Hg 546n m)
  • Absorbance Range : 0.002 Abs
  • Nucleic acid Range : 1% (0.76 absorbance at 350nm)
  • Protein Range : 0.002 to 300 Abs (equivalent to 10mm optical path)
  • Detection Time : 0.4 to 15000 ng/μl (ds-DNA)
  • Machine Size : 0.01 to 400 mg/ml (BSA)
  • Weight : less than 3s
  • Light Source : 20×30×20 cm
  • Detector : 3.5 kg

$23.34

Micro Spectrophotometer TRMS-604
Micro Spectrophotometer TRMS-604
  • Wavelength Range : 190 to 850 nm
  • Wavelength Accuracy : ± 1 nm
  • Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
  • Repeatability : <± 0.5 nm
  • Light Path : 1 mm, 0.05 mm (optical path automatic conversion)
  • Nucleic Acid measurement range : 0.2 to 37500 mg / μl (sa DNA)
  • Protein measurement range : 0.01 to 1120 mg / ml (BSA)
  • sample volume requirements : 0.3 to 2 μl
  • Absorbance Accuracy : 1% (0.76 absorbance at 350 nm)
  • Absorbance Range : 0.002 to 300 Abs (equivalent to 10mm path length)
  • Sample measurement time : less than 3s
  • Sample base material : stainless steel and quartz fiber
  • Light Source : long life pulsed xenon flash lamp
  • Detector : 2048(CMOS) element linear silicide CCD array

$23.34

Micro Spectrophotometer TRMS-605
Micro Spectrophotometer TRMS-605
  • Wavelength Range : 190 to 850 nm
  • Wavelength Accuracy : ± 1nm
  • Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
  • Repeatability : <± 0.5 nm
  • Light Path : 1 mm, 0.05 mm (optical path automatic conversion)
  • Absorbance Accuracy : 1% (0.76 absorbance at 350 nm)
  • Absorbance Range : 0.002 to 300Abs (equivalent to 10mm path length)
  • sample volume Requirements : 0.3 to 2 μl
  • Cuvette Specifications : 1 mm, 2 mm, 5 mm, 10 mm
  • Min sample volume of the cuvette : 20 μl
  • The minimum height of the cuvette sample : 5 mm
  • Temperature Control : 4 to 42 ℃ thermostat adjustable temperature error <± 0.5 ℃
  • Nucleic Acid measurement range : 0.2 to 37500 mg / μl (sa DNA)
  • Protein measurement range : 0.01 to 1120 mg / ml (BSA)
  • Sample measurement time : less than 3s
  • Sample base material : stainless steel and quartz fiber
  • Light Source : long life pulsed xenon flash lamp
  • Detector : 2048(CMOS) element linear silicide CCD array

$23.34

Spectrophotometer TRNS-601

Spectrophotometer TRNS-601

  • Wavelength Range : 900 to 1700 nm
  • Wavelength  Accuracy : ±1 nm
  •  Wavelength Reproducibility  : ≤1 nm
  • Wavelength Scanning Interval Absorbance : 1 nm, 4 nm, 8 nm, 16 nm
  • Reproducibility S/N : 0.002 A (at 0.4 A)
  • Scanning Time : ≥ 103 (at 1500 nm)
  • Application Field : ≤2 min
  • Optical system : Liquid dope samples
  • Detector  : grating monochromatic InGaAs
  • Interface : RS232 serial port
  • Dimensions : 570×370×240 mm
  • Weight : 18 Kg

$23.34

Single Beam UV VIS SpectrophotometerTRSUV-601

Single Beam UV VIS SpectrophotometerTRSUV-601

  • Photometry : Split Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
  • Grating : 1200 lines/mm
  • Detector : Silicon Photocell
  • Spectrum Bandwidth : 2 nm
  • Wavelength Range : 190 to 1100 nm
  • Wavelength Accuracy : ± 0.5 nm
  • Wavelength Repeatability : ≤ 0.2 nm
  • Photometric Range : 0.0 to 200.0% T -0.301 to 4.000A 0.000 to 9999C
  • Photometric Accuracy : ± 0.3% T ± 0.002Abs (0 to 0.5A) ± 0.004Abs (0.5 to 1A)
  • Photometric Repeatability : ≤ 0.15% T 0.001Abs (0 to 0.5A) 0.002Abs (0.5 to 1A)
  • Wavelength Scanning Speed : Fast, medium, slow
  • Baseline Flatness : ≤ ± 0.002 A
  • Stray Light : ≤ 0.03% (measured by NaI at 220 nm) (measured at NaNO2 at 360 nm)
  • Noise : 100%(T) noise ≤ 0.15% (T), 0% (T) noise ≤ 0.1% (T)
  • Baseline Drift : ± 0.0009 Abs / h (250 nm and 500 nm after preheat warm up for 2 hours )
  • Power : AC 220 V± 22 V, 50 Hz± 1 Hz, 200 W
  • COM Port : USB
  • Packing Size : 740 mm×630 mm×450 mm
  • Weight : 0.21m³, 35kg

$23.34

Single Beam UV VIS SpectrophotometerTRSUV-602
Single Beam UV VIS SpectrophotometerTRSUV-602
  • Photometry : Split Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
  • Grating : 1200 lines/mm
  • Detector : Silicon Photocell
  • Spectrum Bandwidth : 2 nm
  • Wavelength Range : 190 to 1100 nm
  • Wavelength Accuracy : ± 0.5 nm
  • Wavelength Repeatability : ≤ 0.2 nm
  • Photometric Range : 0.0 to 200.0% T -0.301 to 4.000A 0.000 to 9999C
  • Photometric Accuracy : ± 0.3% T ± 0.002Abs (0 to 0.5A) ± 0.004Abs (0.5 to 1A)
  • Photometric Repeatability : ≤ 0.15% T 0.001Abs (0 to 0.5A) 0.002Abs (0.5 to 1A)
  • Wavelength Scanning Speed : -
  • Baseline Flatness : -
  • Stray Light : ≤ 0.05% (measured by NaI at 220 nm) (measured at NaNO2 at 360 nm)
  • Noise : 100%(T) noise ≤ 0.15% (T), 0% (T) noise ≤ 0.1% (T)
  • Baseline Drift : ± 0.0009 Abs / h (250 nm and 500 nm after preheat warm up for 2 hours )
  • Power : AC 220 V± 22 V, 50 Hz± 1 Hz, 200 W
  • COM Port : USB
  • Packing Size : 740 mm×630 mm×450 mm
  • Weight : 0.21m³, 35kg

$23.34

Single Beam UV VIS SpectrophotometerTRSUV-603
Single Beam UV VIS SpectrophotometerTRSUV-603
  • Photometry : Split Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
  • Grating : 1200 lines/mm
  • Detector : Silicon Photocell
  • Spectrum Bandwidth : 2 nm
  • Wavelength Range : 325 to 1100 nm
  • Wavelength Accuracy : ± 0.5 nm
  • Wavelength Repeatability : ≤ 0.2 nm
  • Photometric Range : 0.0 to 200.0 % T -0.301 to 4.000 A 0.000 to 9999 C
  • Photometric Accuracy : ± 0.5 % T
  • Photometric Repeatability : ≤ 0.2 % T
  • Wavelength Scanning Speed : Fast, medium, slow
  • Baseline Flatness : ≤ ± 0.002 A
  • Stray Light : ≤ 0.05 % (measured at NaNO2 at 360 nm)
  • Noise : 100%(T) noise ≤ 0.2% (T), 0% (T) noise ≤ 0.1% (T)
  • Baseline Drift : ± 0.0009 Abs / h ( 500 nm after preheat warm up for 2 hours )
  • Power : AC 220 V± 22 V, 50 Hz± 1 Hz, 120 W
  • COM Port : USB
  • Packing Size : 740 mm×630 mm×450 mm
  • Weight : 0.21m³, 35kg

$23.34

Single Beam UV VIS SpectrophotometerTRSUV-604

Single Beam UV VIS SpectrophotometerTRSUV-604

  • Photometry : Split Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
  • Grating : 1200 lines/mm
  • Detector : Silicon Photocell
  • Spectrum Bandwidth : 2 nm
  • Wavelength Range : 325 to 1100 nm
  • Wavelength Accuracy : ± 0.5 nm
  • Wavelength Repeatability : ≤ 0.2 nm
  • Photometric Range : 0.0 to 200.0 % T -0.301 to 4.000 A 0.000 to 9999 C
  • Photometric Accuracy : ± 0.5 % T
  • Photometric Repeatability : ≤ 0.2 % T
  • Wavelength Scanning Speed : -
  • Baseline Flatness : -
  • Stray Light : ≤ 0.05 % (measured at NaNO2 at 360 nm)
  • Noise : 100%(T) noise ≤ 0.2% (T), 0% (T) noise ≤ 0.1% (T)
  • Baseline Drift : ± 0.0009 Abs / h ( 500 nm after preheat warm up for 2 hours )
  • Power : AC 220 V± 22 V, 50 Hz± 1 Hz, 120 W
  • COM Port : USB
  • Packing Size : 740 mm×630 mm×450 mm
  • Weight : 0.21m³, 35kg

$23.34

Single Beam UV VIS Spectrophotometer TRSUV-605

Single Beam UV VIS Spectrophotometer TRSUV-605

  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
  • Grating : 1200 lines/mm
  • Detector : Silicon Photocell
  • Spectrum Bandwidth : 2nm
  • Wavelength Range : 190 to 1100 nm
  • Wavelength Accuracy : ± 1 nm
  • Wavelength Repeatability : ≤ 0.5 nm
  • Photometric Range : 0.0 to 200.0% T, -0.301 to 4.000A, 0.000 to 9999C
  • Photometric Accuracy : ± 0.3% T, ± 0.002Abs (0 to 0.5 A) ± 0.004Abs (0.5 to 1 A)
  • Photometric Repeatability : ≤ 0.15% T, 0.001Abs (0 to 0.5 A) 0.002Abs (0.5 to 1 A)
  • Wavelength Scanning Speed : Fast, medium, slow
  • Baseline Flatness : ≤ ± 0.003 A(200 to 1090 nm)
  • Stray Light : ≤ 0.1% ( at 220 nm NaI ; at 360 nm NaNO2)
  • Noise : 100%(T) noise ≤ 0.5% (T), 0% (T) noise ≤ 0.2% (T)
  • Baseline Drift : ± 0.002 Abs / 30 mins (250 nm and 500 nm after preheating warm-up for 2 hours )
  • Power : AC220 V ± 22 V, 50Hz ± 1Hz, 180 W
  • Packing Size : 630 mm×610 mm×500 mm
  • Weight : 0.16m³, 25 Kg

$23.34

Single Beam UV VIS Spectrophotometer TRSUV-606
Single Beam UV VIS Spectrophotometer TRSUV-606
  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
  • Grating : 1200 lines/mm
  • Detector : Silicon Photocell
  • Spectrum Bandwidth : 2nm
  • Wavelength Range : 190 to 1100 nm
  • Wavelength Accuracy : ± 1 nm
  • Wavelength Repeatability : ≤ 0.5 nm
  • Photometric Range : 0.0 to 200.0% T,  -0.301 to 4.000A, 0.000 to 9999C
  • Photometric Accuracy : ± 0.3% T, ± 0.002Abs (0 to 0.5 A) ± 0.004Abs (0.5 to 1 A)
  • Photometric Repeatability : ≤ 0.15% T, 0.001Abs (0 to 0.5 A) 0.002Abs (0.5 to 1 A)
  • Wavelength Scanning Speed : -
  • Baseline Flatness : -
  • Stray Light : ≤ 0.1% ( at 220 nm NaI ; at 360 nm NaNO2)
  • Noise : 100%(T) noise ≤ 0.5% (T), 0% (T) noise ≤ 0.2% (T)
  • Baseline Drift : ± 0.002 Abs / 30 mins (250 nm and 500 nm after preheating warm-up for 2 hours )
  • Power : AC220 V ± 22 V, 50Hz ± 1Hz, 180 W
  • Packing Size : 630 mm×610 mm×500 mm
  • Weight : 0.16m³, 25 Kg

$23.34

Single Beam UV VIS SpectrophotometerTRSUV-607
Single Beam UV VIS SpectrophotometerTRSUV-607
  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
  • Grating : 1200 lines/mm
  • Detector : Silicon Photocell
  • Spectrum Bandwidth : 4 nm
  • Wavelength Range : 325 to 1100 nm
  • Wavelength Accuracy : ± 1 nm
  • Wavelength Repeatability : ≤ 0.5 nm
  • Photometric Range : 0.0 to 200.0 % T
    -0.301 to 4.000 A
    0.000 to 9999 C
  • Photometric Accuracy : ± 0.3% T, ± 0.002Abs (0 to 0.5 A)
    ± 0.004Abs (0.5 to 1 A)
  • Photometric Repeatability : ≤ 0.15% T, 0.001Abs (0 to 0.5 A)
    0.002Abs (0.5 to 1 A)
  • Wavelength Scanning Speed : Fast, medium, slow
  • Baseline Flatness : ≤ ± 0.003 A(335 to 1090 nm)
  • Stray Light : ≤ 0.1% T(measured at NaNO2 at 360 nm)
  • Noise : 100%(T) noise ≤ 0.5% (T), 0% (T) noise ≤ 0.2% (T)
  • Baseline Drift : ± 0.002 Abs / 30 mins ( 500nm after preheat warm up for 2 hours )
  • Power : AC220 V ± 22 V, 50Hz ± 1Hz, 100 W
  • Packing Size : 630 mm×610 mm×500 mm
  • Weight : 0.16m³, 25 Kg

$23.34

Single Beam UV VIS SpectrophotometerTRSUV-608

Single Beam UV VIS SpectrophotometerTRSUV-608

  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
  • Grating : 1200 lines/mm
  • Detector : Silicon Photocell
  • Spectrum Bandwidth : 4 nm
  • Wavelength Range : 325 to 1100 nm
  • Wavelength Accuracy : ± 1 nm
  • Wavelength Repeatability : ≤ 0.5 nm
  • Photometric Range : 0.0 to 200.0 % T -0.301 to 4.000 A 0.000 to 9999 C
  • Photometric Accuracy : ± 0.3% T, ± 0.002Abs (0 to 0.5 A)
    ± 0.004Abs (0.5 to 1 A)
  • Photometric Repeatability : ≤ 0.15% T, 0.001Abs (0 to 0.5 A)
    0.002Abs (0.5 to 1 A)
  • Wavelength Scanning Speed : -
  • Baseline Flatness : -
  • Stray Light : ≤ 0.1% T(measured at NaNO2 at 360 nm)
  • Noise : 100%(T) noise ≤ 0.5% (T), 0% (T) noise ≤ 0.2% (T)
  • Baseline Drift : ± 0.002 Abs / 30 mins ( 500nm after preheat warm up for 2 hours )
  • Power : AC220 V ± 22 V, 50Hz ± 1Hz, 100 W
  • Packing Size : 630 mm×610 mm×500 mm
  • Weight : 0.16m³, 25 Kg

$23.34

Visible Spectrophotometer TRVS-601

Visible Spectrophotometer TRVS-601

  • Photometry : Single beam
  • Monochromatic Type : Littrow
  • Focal Length : 160 mm
  • Wavelength Setting : Manual Turn Knob
  • Wavelength Range : 325 to1000 nm
  • Wavelength Accuracy : ± 2 nm
  • Wavelength Repeatability : ≤ 1 nm
  • Cuvette Holder Size : 10 mm
  • Photometric Range : 0.0 to 100.0% T, 0 to 1.999A, 0 to 1999C
  • Photometric Accuracy : ± 0.5% T
  • Photometric Repeatability : ≤ 0.2% T
  • Spectrum Bandwidth : 2 nm
  • Grating : 1200 lines/mm
  • Detector : Silicon Photocell
  • Stray Light : ≤ 0.1% ( at 360 nm NaNO2 )
  • Noise : 100%(T) noise ≤ 0.3% (T), 0% (T) noise ≤ 0.2% (T)
  • Drift : ± 0.5% T/3 min
  • Power : AC220v±22v,50Hz± 1Hz, 80W
  • Packing Size : 580×460×340 mm
  • Weight : 0.1CBM, 14 Kg

$23.34

Energy Dispersion X-ray Fluorescence Spectrometer TRXS-601
Energy Dispersion X-ray Fluorescence Spectrometer TRXS-601
  • Analysis Principle : Energy-dispersive X-ray fluorescence analysis
  • Element Measuring Range : Any element from Na(11)-U(92)
  • Minimum Measuring Limit : Cd/Hg/Br/Cr/Pb≤2 ppm
  • Sample Shape : Arbitrary size, any irregular shape
  • Sample Type : Plastic/metal/film/powder/liquid etc.
  • X-Ray Tube : Mo, 5 to 50 KV, 1 to 1000 A
  • Sample Exposure Diameter : 2, 5, 8 mm
  • Detector : Si-PIN or SDD detector, high-speed pulse height analysis system
  • SDD Detector : < 145 eV, > 1000/S, > 15 mm2, 0.025 mm, < 1.2 W
  • High Voltage Generator : Special HV generator for X fluorescence
  • Adc : 2048 channels
  • Filter : 6 filters
  • Sample Observation : 200×color CCD camera
  • Analysis Time : 30 to 900seconds, adjustable
  • System Power Control : +5 VDC at 250 mA (1.2 W)
  • Constant Cooling Control : 400 VDC
  • Channels : 2048 
  • Input : 85 to 265VAC,47 to 63 Hz
  • Voltage Variation : 0.0001
  • Current Variation : 0 to rated power
  • Temperature Variation : voltage or current setting
  • Stability : 0.05%/8 h
  • Working Environment : Temperature 10 to 35 ˚C
    Humidity 30 to 70% RH

$23.34